  1. This file contains general information about Datafit version 2.2 and 
  2. Viewplot version 2.2 by Engineered Software.
  3.  
  4. For the most up to date release notes and version information, look at
  5. our home page on the web. The URL is: http://www.kagi.com/authors/johng/
  6.  
  7. Table of Contents:
  8.  
  9. Section 1 - What is Datafit/Viewplot?
  10. Section 2 - Machine Requirements
  11. Section 3 - Distribution and License Information
  12. Section 4 - Automatic Installation using SETUP.EXE
  13. Section 5 - Version 2.2 and previous Release Notes
  14. Section 6 - Contacting us
  15. Section 7 - Thank you
  16.  
  17. Section 1 - What is Datafit/Viewplot?
  18.  
  19. Datafit is an an Engineering tool which is useful for generating
  20. functional equations and FFT calculations for tabular sampled
  21. data.  It allows the user to import the data from a tab, comma, or space
  22. delimited file or enter it through a built in editor.  For curve fitting, 
  23. Cubic Splines and Least Squares techniques are used. The equation 
  24. coefficients and calculated vs. entered data can be displayed and printed 
  25. in tabular format.  Statistics, such as correlation between entered and 
  26. calculated data, are also calculated. Once equation coefficients are 
  27. determined, the program can generate subroutine source code (Basic and C) 
  28. which can readily be compiled and used to interpolate the data in user 
  29. written programs.  FFT calculations can be done on the entered data directly, 
  30. or can be first spline fitted to allow a faster sampling rate.  The FFT
  31. magnitude and phase calculations can also be displayed and printed in
  32. tabular format. In addition, output from this program for both the curve
  33. fitting functions and FFT calculations can be fed into Viewplot and the
  34. results can be viewed and compared graphically.
  35.  
  36. Viewplot is an Engineering tool which is useful for plotting raw data, or
  37. functional equations and FFT calculations generated by the program Datafit. 
  38. It can be used stand-alone, or launched from within Datafit once the programs 
  39. have been registered.  It has the ability to plot multiple curves from one 
  40. or more datasets and display them in the same or separate windows
  41. simultaneously.  Plots can be customized by formatting legends, numerical
  42. scaling, line colors, line styles and axis/title labels and fonts.  The plots 
  43. can be saved, printed or copied to the Windows clipboard for pasting into 
  44. other applications.
  45.  
  46. Section 2 - Machine Requirements
  47.  
  48. Datafit/Viewplot version 2.2 is supported on Windows 3.1, Windows '95, 
  49. and Windows NT version 3.51.  The memory requirement is that you have
  50. enough to run Windows or Windows NT.  If you are pushing your machine
  51. to the limit with just the operating system, make sure you have virtual
  52. memory (swap space) allocated.  The programs now support all windows
  53. supported video resolutions.
  54.  
  55. Section 3 - Distribution and License Information
  56.  
  57. The software is being distributed as Shareware.  You may evaluate
  58. it free of charge for 15 days. If, after the 15 day evaluation period, 
  59. you choose to continue using the software, you must register it.  
  60. Register your copy of Datafit/Viewplot by selecting "Complete 
  61. Registration Form" in the Registration Information panel from either
  62. program, or double-click the "Register" icon. You only need to complete 
  63. one form. Follow the instructions shown to you in the registration panels.  
  64. This program relies on your support for continued development, 
  65. and single user registration is only $30.00. This price covers the use of 
  66. both programs. When you register Datafit/Viewplot, you will receive 
  67. a code that enables additional features and you will become eligible for 
  68. priority support. You will also be able to obtain free updates of the 
  69. programs through our Web page (address below) with which you can use your 
  70. current registration code, until the next major release. 
  71.  
  72. To register copies of Datafit/Viewplot please use the "Register" program 
  73. provided with Datafit/Viewplot to make payments. We use KAGI Shareware 
  74. registration service, which accepts different payment methods, including 
  75. credit card and invoices. If you live in the US or Canada you may also 
  76. mail us your check or money order directly, payable to John A. Gilmore, 
  77. at the following address:
  78.  
  79.  Engineered Software
  80.  C/O John A. Gilmore
  81.  1315 Varner Road
  82.  Pittsburgh, PA 15227, USA
  83.  
  84. Once we receive the form, you will receive a confirmation letter which 
  85. will include your registration number and license agreement.  Once you 
  86. have received a registration number, you may permanently enter it by 
  87. selecting "Enter Registration" from the registration information panel.  
  88. Be sure to enter your name EXACTLY how it is spelled on the confirmation 
  89. letter. If you have any problems entering your registration number, please 
  90. contact technical support. For more information about registering the 
  91. software, see "Obtaining a License for Datafit/Viewplot" in the online help.
  92.  
  93. Distribution is permitted provided you follow these instructions:  You are 
  94. free to make copies of the distribution archive (DTAFITxx.ZIP) and pass 
  95. it along to others for evaluation provided that no modifications or 
  96. additions are made to the software, its documentation, or any associated 
  97. files.  
  98.  
  99. The URL for our home page is: http://www.kagi.com/authors/johng/
  100. Don't forget the trailing slash!  This page is updated for each release of
  101. the software, so you can check here for new release information.
  102.  
  103. Section 4 - Automatic Installation using SETUP.EXE
  104.  
  105. To automatically install Datafit/Viewplot for Windows on your hard drive:
  106.  
  107. 1. If you have received the software from an archive in the form of a .ZIP 
  108.    file, copy the contents of the archive to a temporary directory and unzip
  109.    the files. Copy the unzipped files to a floppy disk to keep as a backup.
  110.    If you have received the software on a floppy disk directly from
  111.    Engineered Software, the files will already be unzipped. 
  112.  
  113. 2. Place the disk in a floppy drive of your computer if you are installing 
  114.    from the floppy disk.
  115.  
  116. 3. Open the File menu of the Windows program manager (if you are running
  117.    Windows 3.1 or Windows NT) and select Run, or click on the "Start" button
  118.    and select Run... (if you are running Windows '95).
  119.  
  120. 4. In the Run dialog box, type A:SETUP or B:SETUP, depending on the  
  121.    drive used.
  122.  
  123. 5. The Setup application will prompt you for additional information as 
  124.    required.
  125.  
  126. Section 5 - Version 2.2 and Previous Release Notes
  127.  
  128. Datafit and Viewplot Version 2.2 is a FREE upgrade for current Version 2.1 
  129. and previous users.  Not every upgrade will be free, but interim releases
  130. will be. If there is a charge for upgrades in the future, it will be somewhat
  131. less than purchasing it for the first time.  If you register the software,
  132. you will be notified of new releases.  Work is going on on a daily basis,
  133. so register the software and submit your requests.  We can't guarantee that
  134. we will honor every feature request, but we will do our best.
  135.  
  136. Changes/Bug Fixes in Datafit and Viewplot Version 2.2
  137.  
  138. 1.  If only notes text changes, user is prompted to save only notes text so
  139.     that solution is not deleted.
  140.     Changed Code in Datafit (1/5/96)
  141.  
  142. 2.  Call REGISTER.EXE from application directory instead of path in both
  143.     Datafit and Viewplot to avoid getting an old copy from different
  144.     directory.
  145.     Changed Code in Datafit and Viewplot (1/5/96)
  146.  
  147. 3.  Allow commas to be entered as decimal points and updated file structure
  148.     for international support.
  149.     Changed Code in Datafit and Viewplot (12/25/95)
  150.  
  151. 4.  Correlation now listed along with equation in Export function panel in
  152.     Datafit and Viewplot Graph List.
  153.     Added Code in Datafit and Viewplot (12/23/95)
  154.  
  155. 5.  Double click on project name did not function in project panel when
  156.     opening a new project, or in Export Function Panel.
  157.     Added code in Datafit (12/23/95)
  158.  
  159. 6.  Equation 8 under common functions never got listed when it solved
  160.     successfully.
  161.     Fixed code in Datafit (12/19/95)
  162.  
  163. 7.  Added Equation numbers to default text strings (for equation viewing
  164.     and default legends) for common Equations.
  165.     Added Code in Datafit and Viewplot (12/19/95)
  166.  
  167. 8.  When solving, if either data points passed through zero, value was made
  168.     small. This is no longer done, it introduced small error in solution
  169.     equations.
  170.     Changed Code in Datafit (12/19/95)
  171.  
  172. 9.  Made all full screen panels in Datafit now resizable. Buttons and text
  173.     repositioned upon resizing. Now support 640x480 resolutions and smaller.
  174.     Added Code in Datafit (12/18/95)
  175.  
  176. 10. Replaced (X,Y) data list boxes in Datafit with two column tables so
  177.     that data positioning no longer a function of font.
  178.     Changed code in Datafit (12/15/95)
  179.  
  180. 11. Added "Fonts" button in "Format Axis" panel of Viewplot to enable
  181.     changing plot fonts.
  182.     Added Code in Viewplot (12/15/95)
  183.  
  184. 12. Added User defined options in Datafit.  Includes default Font
  185.     designations and window sizes.
  186.     Added Code in Datafit (12/14/95)
  187.  
  188. 13. Added User defined options in Viewplot. Includes default Font
  189.     designations and window sizes.
  190.     Added Code in Viewplot (12/14/95)
  191.  
  192. 14. Added data Exchange capabability in Datafit Data Entry Panel. 
  193.     Added Code in Datafit (12/13/95)
  194.  
  195. 15. Added data Sorting capability in Data Entry Panel. 
  196.     Added Code in Datafit (12/13/95)
  197.  
  198. 16. Redesigned Data Entry Panel, more functionality with less keyboard entry.
  199.     Changed Code in Datafit (12/12/95)
  200.  
  201. 17. Added capability to import tab, comma, and space delimited files in
  202.     Data Entry Panel.
  203.     Added Code in Datafit (12/6/95)
  204.  
  205. 18. Added capability to import tab, comma, and space delimited files
  206.     directly into Viewplot for Plotting.
  207.     Added Code in Viewplot (12/5/95)
  208.  
  209. 19. Added "Plot as continuous" check box in "Format Graphs" panel in
  210.     Viewplot to allow plotting discreet data as continuous lines.
  211.     Added Code in Viewplot (12/3/95)
  212.  
  213. 20. Changed 'splash' screens in Datafit and Viewplot.
  214.     Fixed Code in Datafit and Viewplot (12/1/95)
  215.  
  216. 21. Control and background colors now use Windows 'system' colors.
  217.     Changed Code in Datafit and Viewplot (11/27/95)
  218.  
  219. 22. Files saved as plot files containing Least Squares Polynomial equations
  220.     had line missing in file structure.
  221.     Fixed Code in Viewplot (11/25/95)
  222.  
  223. Changes/Bug Fixes in Datafit and Viewplot Version 2.1
  224.  
  225. 1.  Text note box was added. This allows the user to type notes in the
  226.     text box which are saved along with the projects. See the section
  227.     "Entering Notes" in the online help.
  228.  
  229. 2.  FFT capabilities added. See the section "FFT Calculations" in the
  230.     online help.
  231.  
  232. 3.  The calculated Y data for Cubic Splines was corrected in the View
  233.     Equations/Statistics Panel. Previously the calculated data was 
  234.     displayed incorrectly because the solved coefficient data was
  235.     not read in as double precision.
  236.  
  237. 4.  The installation program previously overwrote the datafit.ini
  238.     and viewplot.ini files in the Windows directory if the software
  239.     had already been installed. If the files already exist, they will
  240.     no longer be overwritten.
  241.  
  242. 5.  Backward file compatility exists to previous versions.
  243.  
  244. 6.  If the default windows fonts Courier, Ms Sans Serif, or Arial
  245.     were not present on the users system, the user would get an error
  246.     which said "Invalid Property Value". A more descriptive error
  247.     message comes up, and the program continues with the windows system
  248.     standard font.
  249.  
  250. 7.  If the screen resolution is less than 800 x 600, a warning panel
  251.     tells the user to change his screen resolution to a minimum of
  252.     800 x 600. The software will continue, but there will not be enough
  253.     screen real estate to display the screens, hence buttons and text
  254.     may not show up.
  255.  
  256. 8.  We now accept payment of various forms. See section 3 above.
  257.  
  258. 9.  Adding printing status panels.
  259.  
  260. 10. The ability to display FFT calculations was added.
  261.  
  262. 11. The default axis limits initialize to more 'reasonable' values
  263.     instead of fitting to max and min values.
  264.  
  265. 12. Input data is now displayed at the top of the equation list when
  266.     opening or importing a new file.
  267.  
  268. 13. Added 3D check boxes in colors and line style panels.
  269.  
  270. 14. The ability to view plot coordinates by clicking was added. See
  271.     the section "Show Coordinates" in the online help.
  272.  
  273. 15. Backward file compatility exists to previous versions.
  274.  
  275. 16. Adding printing status panels in Viewplot.
  276.  
  277. Changes/Bug Fixes in Datafit and Viewplot Version 2.0:
  278.  
  279. 1.  Added additional Least Squares functions.  These are common functions 
  280.     used in scientific and statistical analysis.  See the section "Specifying 
  281.     Equation Types" in the online help.
  282.  
  283. 2.  Added ability to export source code in C and Basic to readily include 
  284.     the solved equations in other source code.  See the section "Exporting 
  285.     Program Subroutines" in the online help.
  286.  
  287. 3.  Revised the View menu to more easily view the solution parameters.  See 
  288.     the section "Viewing Output" in the online help.
  289.  
  290. 4.  You can now access Viewplot directly from Datafit.  The software must 
  291.     be registered before this feature can be accessed.  See the section 
  292.     "Viewing Output" in the online help.
  293.  
  294. 5.  Viewplot can run in either standalone mode as before, or can be accessed 
  295.     directly from Datafit.  The software must be registered before this 
  296.     feature can be accessed.  See the section "Viewing Output" in the Datafit 
  297.     online help.
  298.  
  299. Stay tuned.  Some more neat stuff is on the way....
  300.  
  301. Section 6 - Contacting us
  302.  
  303. If you have any questions or problems installing or setting up the programs,
  304. you may contact us via email at johng@kagi.com, or by US Mail at:
  305.  
  306. Engineered Software
  307. C/O John A. Gilmore
  308. 1315 Varner Road
  309. Pittsburgh, PA 15227
  310.  
  311. The URL for our home page is: http://www.kagi.com/authors/johng/
  312. Don't forget the trailing slash!
  313.  
  314. For more information, please see the section "Obtaining Technical Support"
  315. in the online help.
  316.  
  317. Section 7 - Thank you
  318.  
  319. Thank you for taking the time to evaluate this software. We hope it does
  320. what you need easily and efficiently. If you have any comments, good or bad,
  321. PLEASE send them to the address in Section 6.
  322.  
  323.  
  324.  
  325.  
  326.  